80 questions shown in Electrical and Electronics Measurement. Filter for cleaner practice sessions.

Showing Electrical and Electronics Measurement PYQs from Electrical Engineering.
2025 PYQ

The maximum percentage error in the equivalent resistance of two parallel connected resistors of $100 \Omega$ and $900 \Omega$ with each having a maximum $5 \%$ error is __________...

Electrical and Electronics Measurement/NAT/explanation
2024 PYQ

The table lists two instrument transformers and their features: Instrument Transformers Features X) Current Transformer (CT) P) Primary is connected in parallel to the grid Y) Pote...

Electrical and Electronics Measurement/MTF/answer key
2022 PYQ

A balanced Wheatsone bridge ABCD has the following arm resistances : R AB = 1 k$$\Omega$$ $$\pm$$ 2.1%; R BC = 100 $$\Omega$$ $$\pm$$ 0.5%; R CD is an unknown resistance; R DA = 30...

Electrical and Electronics Measurement/MCQ/answer key/explanation
2021 PYQ

Inductance is measured by,

Electrical and Electronics Measurement/MCQ/answer key/explanation
2018 PYQ

Two wattmeter method is used for measurement of power in a balanced three-phase load supplied from a balanced three-phase system. If one of the wattmeters reads half of the other (...

Electrical and Electronics Measurement/MCQ/answer key
2018 PYQ

A 0-1 Ampere moving iron ammeter has an internal resistance of 50 m$$\Omega $$ and inductance of 0.1 mH. A shunt coil is connected to extend its range to 0-10 Ampere for all operat...

Electrical and Electronics Measurement/MCQ/answer key
2017 PYQ

The slope and level detector circuit in a CRO has a delay of 100 ns. The start-stop sweep generator has a response time of 50 ns. In order to display correctly, a delay line of

Electrical and Electronics Measurement/MCQ/answer key
2017 PYQ

A stationary closed Lissajous pattern on an oscilloscope has $$3$$ horizontal tangencies and $$2$$ vertical tangencies for a horizontal input with frequency $$3$$ $$kHZ.$$ The freq...

Electrical and Electronics Measurement/MCQ/answer key
2017 PYQ

The following measurements are obtained on a single phase load: $$V = 220 V$$ $$ \pm $$$$1$$%. $${\rm I}$$$$= 5.0$$ $$A$$ $$ \pm \,1$$% and $$W=555$$ $$W$$ $$ \pm \,2$$%. If the po...

Electrical and Electronics Measurement/NAT
2017 PYQ

A $$10{\raise0.5ex\hbox{$\scriptstyle 1$} \kern-0.1em/\kern-0.15em \lower0.25ex\hbox{$\scriptstyle 2$}}$$ digit timer counter possesses a base clock of frequency $$100$$ $$MHz$$. W...

Electrical and Electronics Measurement/NAT
2017 PYQ

Two resistors with nominal resistance values $${R_1}$$ and $${R_2}$$ have additive uncertainties $$\Delta {R_1}$$ and $$\Delta {R_2},$$ respectively. When these resistances are con...

Electrical and Electronics Measurement/MCQ/answer key
2016 PYQ

A dc voltage with ripple is given by $$v\left( t \right)\,\,\,\, = \,\,\,\,\left[ {100 + 10\sin \left( {\omega t} \right) - 5\sin \left( {3\omega t} \right)} \right]$$ volts. Measu...

Electrical and Electronics Measurement/NAT
2015 PYQ

A ($$0-50$$ $$A$$) moving coil ammeter has a voltage drop of $$0.1$$ $$V$$ across its terminals at full scale deflection. The external shunt resistance (in $$milliohms$$) needed to...

Electrical and Electronics Measurement/NAT
2015 PYQ

A 3-phase balanced load which has a power factor of 0.707 is connected to a balanced supply. The power consumed by the load is 5 kW. The power is measured by the two-wattmeter meth...

Electrical and Electronics Measurement/MCQ/answer key
2014 PYQ

Two ammeters $$X$$ and $$Y$$ have resistances of $$1.2$$ $$\Omega $$ and $$1.5$$ $$\Omega $$ respectively and they give full-scale deflection with $$150$$ $$mA$$ and $$250$$ $$mA$$...

Electrical and Electronics Measurement/NAT
2014 PYQ

A periodic waveform observed across a load is represented by $$$V\left( t \right) = \left\{ {\matrix{ {1 + \sin \,\omega t} & {0 \le \omega t < 6\pi } \cr { - 1 + \sin \,\omega t}...

Electrical and Electronics Measurement/MCQ/answer key
2014 PYQ

Power consumed by a balanced $$3$$-phase, $$3$$-wire load is measured by the two wattmeter method. The first wattmeter reads twice that of the second. Then the load impedance angle...

Electrical and Electronics Measurement/MCQ/answer key
2014 PYQ

An $$LPF$$ wattmeter of power factor $$0.2$$ is having three voltage settings $$300V,$$ $$150V$$ and $$75V,$$ and two current settings $$5 A$$ and $$10A.$$ The full scale reading i...

Electrical and Electronics Measurement/NAT
2014 PYQ

The dc current flowing in a circuit is measured by two ammeters, one PMMC and another electrodynamometer type, connected in series. The PMMC meter contains 100 turns in the coil, t...

Electrical and Electronics Measurement/NAT
2014 PYQ

While measuring power of a three-phase balanced load by the two-wattmeter method, the readings are $$100$$ $$W$$ and $$250$$ $$W$$. The power factor of the load is ___________.

Electrical and Electronics Measurement/NAT
2014 PYQ

In an oscilloscope screen, linear sweep is applied at the

Electrical and Electronics Measurement/MCQ/answer key
2014 PYQ

Suppose that resistors $${R_1}$$ ܴand $${R_2}$$ ܴare connected in parallel to give an equivalent resistor $$R.$$ If resistors ܴ$${R_1}$$ and $${R_2}$$ ܴ have tolerance of $$1$$% ea...

Electrical and Electronics Measurement/MCQ/answer key
2012 PYQ

The bridge method commonly used for finding mutual inductance is

Electrical and Electronics Measurement/MCQ/answer key
2012 PYQ

An analog voltmeter uses external multiplier settings. With a multiplier setting of $$20\,\,k\Omega ,$$ it reads $$440$$ $$V$$ and with a multiplier setting of $$80$$ $$k\Omega ,$$...

Electrical and Electronics Measurement/MCQ/answer key
2011 PYQ

Consider the following statement: (i) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil. (ii) The compensating coil...

Electrical and Electronics Measurement/STMT/answer key
2011 PYQ

A $$4\,{1 \over 2}$$ digit $$DMM$$ has the error specification as $$0.2$$% of reading $$+10$$ counts. If a dc voltage of $$100$$ $$v$$ is read on its $$200$$ $$V$$ full scale. The...

Electrical and Electronics Measurement/MCQ/answer key
2011 PYQ

A dual trace oscilloscope is set to operate in the ALTernate. The control input of the multiplexer used in the y-circuit is fed with a signal having a frequency equal to

Electrical and Electronics Measurement/MCQ/answer key
2010 PYQ

An ammeter has a current range of $$0$$-$$5A,$$ and its internal resistance is $$0.2\Omega $$. In order to change the range to $$0$$-$$25$$ $$A$$ we need to add a resistance of

Electrical and Electronics Measurement/MCQ/answer key
2009 PYQ

The two inputs of a $$CRO$$ are fed with two stationary periodic signals. In the $$X$$-$$Y$$ mode, the screen shows a figure which changes from ellipse to circle and back to ellips...

Electrical and Electronics Measurement/MCQ/answer key
2009 PYQ

An average-reading digital multimeter reads $$10V$$ when fed with a triangular wave, symmetric about the time axis. For the same input an rms reading meter will read.

Electrical and Electronics Measurement/MCQ/answer key
2008 PYQ

Two $$8$$ $$A$$ $$D$$ $$C$$ $$s$$ one of single slope integrating type and other of successive approximation type. Take $${T_A}$$ and $${T_B}$$ times to connect $$5V$$ analog input...

Electrical and Electronics Measurement/MCQ/answer key
2007 PYQ

A $$3$$ $$V$$ $$dc$$ supply with an internal resistance of $$2\,\,\Omega $$ supplies a passive non-linear resistance characterized by the relation $${V_{NL}} = {\rm I}_{NL}^2.$$ Th...

Electrical and Electronics Measurement/MCQ/answer key
2006 PYQ

A variable $$'w'$$ is related to three other variables $$x, y, z$$ as $$w=xy/z.$$ The variables are measured with meters of accuracy$$ \pm $$ $$0.5$$% reading, $$ \pm 1\% $$ of ful...

Electrical and Electronics Measurement/MCQ/answer key
2006 PYQ

$${R_1}$$ and $${R_2}$$ are the opposite arms of $${R_3}$$ and $${R_4}$$ of a wheat stone bridge. The source voltage is applied across $${R_1}$$ and $${R_3}$$ under balanced condit...

Electrical and Electronics Measurement/MCQ/answer key
2006 PYQ

An energy meter connected to an immersion heater (resistive) operating on an $$AC$$ $$230V,$$ $$50$$ $$Hz,$$ $$AC$$ single phase source reads $$2.3$$ units ($$kWh$$) in $$1$$ hour....

Electrical and Electronics Measurement/MCQ/answer key
2006 PYQ

A current of $$ - 8 + 6\sqrt 2 \left( {\sin \,\omega t + {{30}^0}} \right)\,\,A$$ is passed though three meters. They are a center zero $$PMMC$$ meter, true $$r.m.s$$ meter and mov...

Electrical and Electronics Measurement/MCQ/answer key
2006 PYQ

A $$200/1$$ current transformer $$(CT)$$ is wound with $$200$$ turns on the secondary on a toroidal core. When it carries a current of $$160$$ $$A$$ on the primary, the ratio and p...

Electrical and Electronics Measurement/MCQ/answer key
2005 PYQ

Two wattmeter's, which are connected to measure the total power on a three-phase system supplying a balanced load, read $$10.5$$ $$kW$$ and $$–2.5$$ $$kW$$ respectively. The total...

Electrical and Electronics Measurement/MCQ/answer key
2005 PYQ

The simultaneous application of signals $$x(t)$$ and $$y(t)$$ to the horizontal and vertical plates, respectively, of an oscilloscope, produces a vertical figure-of-$$8$$ display....

Electrical and Electronics Measurement/MCQ/answer key
2005 PYQ

A digital-to-analog converter with a full scale output voltage of $$3.5V$$ has resolution close to $$14mV.$$ It's bit size is _____.

Electrical and Electronics Measurement/MCQ/answer key
2005 PYQ

A DC ammeter has a resistance of $$0.1$$$$\Omega $$ and its current range is $$0$$ – $$100A.$$ If the range is to be extended to $$0$$ –$$500A,$$ the meter requires the following s...

Electrical and Electronics Measurement/MCQ/answer key
2004 PYQ

A $$50$$ $$Hz,$$ bar primary $$CT$$ has a secondary with $$500$$ turns. The secondary supplies $$5A$$ current into a purely resistive burden of $$1\,\Omega $$. The magnetizing ampe...

Electrical and Electronics Measurement/MCQ/answer key
2004 PYQ

A dc A-h meter is rated for 15 A, 250V. The meter constant is 14.4 A-sec/rev. The meter constant at rated voltage may be expressed as

Electrical and Electronics Measurement/MCQ/answer key
2004 PYQ

A moving iron ammeter produces a full scale torque of $$240$$ $$\,\mu Nm$$ with a deflection of $${120^ \circ }$$ at a current of $$10$$ $$A$$. The rate of change of self inductanc...

Electrical and Electronics Measurement/MCQ/answer key
2004 PYQ

The core flux in the $$CT$$ of above problem under the given operating condition is

Electrical and Electronics Measurement/MCQ/answer key
2004 PYQ

A moving coil of a meter has $$100$$ turns, and a length and depth of $$10$$ $$mm$$ and $$20$$ $$mm$$ respectively. It is positioned in a uniform radial flux density of $$200$$ $$m...

Electrical and Electronics Measurement/MCQ/answer key
2004 PYQ

A galvanometer with a full scale current of $$10$$ $$mA$$ has a resistance of $$1000$$$$\Omega $$. The multiplying power (the ratio of measured current to galvanometer current) of...

Electrical and Electronics Measurement/MCQ/answer key
2003 PYQ

The items in List $$-$$ $${\rm I}$$ represent the various types of measurements to be made with a reasonable accuracy using a suitable bridge. The items in List $$-$$ $${\rm II}$$...

Electrical and Electronics Measurement/MTF/answer key
2003 PYQ

The voltage-flux adjustment of a certain $$1$$-phase $$220$$ $$V$$ induction watt-hour meter is altered so that the phase angle between the applied voltage and the flux due to it $...

Electrical and Electronics Measurement/MCQ/answer key
2003 PYQ

A Manganin swamping resistance is connected in series with a moving coil ammeter consisting of a milli-ammeter and a suitable shunt in order to

Electrical and Electronics Measurement/MCQ/answer key
2003 PYQ

The effect of stray magnetic fields on the actuating torque of a portable instrument is maximum when the operating field of the instrument and the stray fields are

Electrical and Electronics Measurement/MCQ/answer key
2003 PYQ

A wattmeter reads $$400$$ $$W$$ when its current coil is connected in the $$R$$ phase and its pressure coil is connected between this phase and the neutral of a symmetrical $$3$$-p...

Electrical and Electronics Measurement/MCQ/answer key
2003 PYQ

A $$500$$ $$A/5$$ $$A,$$ $$50$$ $$Hz$$ current transformer has a bar primary. The secondary burden is a pure resistance of $$1\,\Omega $$ and it draws a current of $$5A$$. If the m...

Electrical and Electronics Measurement/MCQ/answer key
2003 PYQ

The inductance of a certain moving-iron ammeter is expressed as $$L = 10 + 3\theta - {{{\theta ^2}} \over 4}\mu H,\,\,$$ where $$\,\,\theta \,\,\,$$ is the deflection in radians fr...

Electrical and Electronics Measurement/MCQ/answer key
2002 PYQ

Kelvin double bridge is best suited for the measurement of

Electrical and Electronics Measurement/MCQ/answer key
2002 PYQ

Two in-phase, 50Hz sinusoidal waveform of unit amplitude are fed into channel-1. and channel-2 respectively of an oscilloscope, Assuming that the voltage scale, time scale and othe...

Electrical and Electronics Measurement/MCQ/answer key
2001 PYQ

A $$100$$ $$\mu A$$ ammeter has an internal resistance of $$100\,\Omega $$. For extending its range to measure $$500$$ $$\mu A$$, the shunt required is of resistance (in $$\Omega $...

Electrical and Electronics Measurement/MCQ/answer key
2001 PYQ

Resistances $${R_1}$$ and $${R_2}$$ have, respectively, nominal values of $$10\Omega $$ and $$5\Omega ,$$ and tolerances of $$ \pm 5\% $$ and $$ \pm 10\% $$. The range of values fo...

Electrical and Electronics Measurement/MCQ/answer key
2001 PYQ

The minimum number of wattmeter(s) required to measure 3 $$-$$ phase, 3 $$-$$ wire balanced or unbalanced power is

Electrical and Electronics Measurement/MCQ/answer key
2000 PYQ

The two wattmeter method is used to measure active power on a three phase, three wire system. If the phase voltage is unbalanced, then the power reading is

Electrical and Electronics Measurement/MCQ/answer key
2000 PYQ

A $$3$$ - $$\phi $$ load operates with balanced voltages applied to its terminals, and draws balanced currents. The potential coil of a moving coil wattmeter is connected from $$R$...

Electrical and Electronics Measurement/OTHER
2000 PYQ

Instrument transformers are known to introduce magnitude and phase errors in measurements. These are primarily due to

Electrical and Electronics Measurement/MCQ/answer key
1999 PYQ

A current of $$\left[ {2 + \sqrt 2 \sin \left( {314t + 30} \right) + 2\sqrt 2 \cos \left( {952t + 45} \right)} \right]$$ is measured with a thermocouple type. $$5A$$ full scale, cl...

Electrical and Electronics Measurement/MCQ/answer key
1999 PYQ

Electro dynamic type watt meters have large errors while measuring power in a.c circuits at low power factor conditions, since the voltage across and the current though the

Electrical and Electronics Measurement/MCQ/answer key
1999 PYQ

The voltage phasor of a circuit is $$10\angle {15^ \circ }V$$ and the current phasor is $$2\angle - {45^ \circ }A.$$ The active and the reactive powers in the circuit are

Electrical and Electronics Measurement/MCQ/answer key
1999 PYQ

For a dual $$ADC$$ type $$3\,\,{1 \over 2}$$ digit $$DVM$$, the reference voltage is $$100mV$$ and the first integration time is set to $$300$$$$ms$$. For some input voltage, the '...

Electrical and Electronics Measurement/MCQ/answer key
1999 PYQ

Two $$100$$ $$\mu A$$ full scale $$PMMC$$ meters are employed to construct a $$10$$ $$V$$ and a $$100$$ $$V$$ full scale voltmeter. These meters will have figures of merit (sensiti...

Electrical and Electronics Measurement/MCQ/answer key
1998 PYQ

A moving coil galvanometer is made into a d.c. ammeter by connecting

Electrical and Electronics Measurement/MCQ/answer key
1998 PYQ

A d.c. voltmeter has a sensitivity of $$1000$$$$\Omega /volt.$$ When it measures half full scale in $$100$$ $$V$$ range, the current through the voltmeter is

Electrical and Electronics Measurement/MCQ/answer key
1997 PYQ

A dynamometer type wattmeter responds to the

Electrical and Electronics Measurement/MCQ/answer key
1997 PYQ

A transfer instrument employed in the standardization of a polar type $$a.c$$ potentiometer is ______

Electrical and Electronics Measurement/MCQ/answer key
1997 PYQ

A potentiometer is basically

Electrical and Electronics Measurement/MCQ/answer key
1997 PYQ

The primary current in a current transformer is dictated by

Electrical and Electronics Measurement/MCQ/answer key
1996 PYQ

An advantage of a permanent magnet moving coil instrument is that it is

Electrical and Electronics Measurement/MCQ/answer key
1996 PYQ

The scale of a voltmeter is uniform. Its type is

Electrical and Electronics Measurement/MCQ/answer key
1996 PYQ

The moving coil in a dynamometer wattmeter is connected

Electrical and Electronics Measurement/MCQ/answer key
1996 PYQ

A water boiler at home is switched on to the $$A.C$$ mains supplying power at $$230$$ $$V/50$$ $$Hz.$$ The frequency of instantaneous power consumed by the boiler is

Electrical and Electronics Measurement/MCQ/answer key
1996 PYQ

For a given frequency, the deflecting torque of an induction ammeter is directly proportional to

Electrical and Electronics Measurement/MCQ/answer key
1995 PYQ

Fringing in capacitive type transducer can be minimized by providing a _________

Electrical and Electronics Measurement/OTHER
1995 PYQ

Two $$100V$$ full scale $$PMMC$$ type D.C voltmeter having figure of merits ($$FOM)$$ of $$10k\Omega /V$$ and $$20k\Omega /V$$ are connected in series. The series combination can b...

Electrical and Electronics Measurement/NAT