2019 Q8

A 5 kVA, 50 V/100 V, single-phase transformer has a secondary terminal voltage of 95 V when loaded. The regulation of the transformer is

medium
2018 Q1

A single-phase 100 kVA, 1000 V / 100 V, 50 Hz transformer has a voltage drop of 5% across its series impedance at full load. Of this, 3% is due to resistance. The percentage regula...

mediumanswer key
2018 Q44

A 25 kVA, 400 V, Δ-connected, 3-phase, cylindrical rotor synchronous generator requires a field current of 5 A to maintain the rated armature current under short-circuit condition....

hardanswer key
2018 PYQ

A single-phase 100 kVA, 1000 V / 100 V, 50 Hz transformer has a voltage drop of 5% across its series impedance at full load. Of this, 3% is due to resistance. The percentage regula...

easyanswer keyelite explanation
2017 PYQ

A $$25$$ $$kVA,$$ $$400$$ $$V,$$ $$\Delta $$ - connected, $$3$$-phase, cylindrical rotor synchronous generator requires a field current of $$5$$ $$A$$ to maintain the rated armatur...

medium
2017 PYQ

A 3-phase 50 Hz generator supplies power of 3 MW at 17.32 kV to a balanced 3-phase inductive load through an overhead line. The per phase line resistance and reactance are 0.25 $$\...

medium
2007 PYQ

In a transformer, zero voltage regulation at full load is

easyanswer key
2006 PYQ

The $$A, B, C, D$$ constant of a $$220$$ $$kV$$ line are: $$A = D = 0.94\,\angle \,10,\,\,\,B = 130\,\angle \,730,\,\,\,C = 0.001\,\angle \,900.\,\,$$ If the sending end voltage of...

mediumanswer key
2000 PYQ

A 3-phase delta/star transformer is supplied at 6000 V on the delta-connected side. The terminal voltage on the secondary side when supplying full load as 0.8 lagging power-factor...

mediumanswer key
2000 PYQ

A single-phase, 2000 V alternator has armature resistance and reactance of 0.8 ohms and 4.94 ohms respectively. The voltage regulation of the alternator at 100 A load at 0.8 leadin...

mediumanswer key
1999 PYQ

A 10 kVA, 400 V/200 V, single phase transformer with a percentage resistance of 3% and percentage reactance of 6% is supplying a current of 50 A to a resistive load. The value of t...

easyanswer key
1997 PYQ

A single-phase alternator has a synchronous reactance of $$2$$ $$ohms$$ and negligible resistance. If it supplies $$10$$ $$A$$ to a purely capacitive load at $$200V,$$ then generat...

medium