All concepts →The initial three-phase voltage phasors ($\bar{V}_A$, $\bar{V}_B$, and $\bar{V}_C$) at a bus of a power network are as shown in Case-1. Due to a disturbance, the bus voltage phasor...
Three single-phase 11kV/3.3kV transformers are connected to form a three-phase transformer bank with connections as shown. Considering ABC phase sequence, the vector group of the t...
In the circuit shown, Z₁ = 50∠ – 90° Ω and Z₂ = 200∠ – 30° Ω. It is supplied by a three phase 400 V source with the phase sequence being R-Y-B. Assume the watt meters W₁ and W₂ to...
A balanced delta connected load consisting of the series connection of one resistor (R = 15 Ω) and a capacitor (C = 212.21 µF) in each phase is connected to three-phase, 50 Hz, 415...
Two wattmeter method is used for measurement of power in a balanced three-phase load supplied from a balanced three-phase system. If one of the wattmeters reads half of the other (...
The load shown in the figure is supplied by a 400 V (line-to-line), 3-phase source (RYB sequence). The load is balanced and inductive, drawing 3464 VA. When the switch S is in posi...
A three-phase load is connected to a three-phase balanced supply as shown in the figure. If $V_{an} = 100\angle 0^\circ$ V, $V_{bn} = 100\angle -120^\circ$ V and $V_{cn} = 100\angl...
A 3-phase, 50 Hz generator supplies power of 3MW at 17.32 kV to a balanced 3-phase inductive load through an overhead line. The per phase line resistance and reactance are 0.25$\Om...
A 3-phase 50 Hz generator supplies power of 3 MW at 17.32 kV to a balanced 3-phase inductive load through an overhead line. The per phase line resistance and reactance are 0.25 $$\...
A three-phase cable is supplying $$800$$ kW and $$600$$ kVAr to an inductive load. It is intended to supply an additional resistive load of $$100$$ kW through the same cable withou...
$$230$$ $$V$$ (phase) $$50$$ Hz, three-phase, $$4$$-wire, system has a sequence $$ABC$$. A unity power-factor load of $$4$$ kW is connected between phase A and neutral $$N$$. It is...
A three phase balanced star connected voltage source with frequency $$\omega \,\,rad/s$$ is connected to a star connected balanced load which is purely inductive. The instantaneous...
A $$400V$$, $$50$$ $$Hz,$$ three phase balanced source supplies power to a star connected load whose rating is $$12\,\,\angle 3\,\,kVA,$$ $$0.8$$ $$pf$$ (lag). The rating $$($$in $...
A $$400$$ V, $$50$$ Hz, three phase balanced source supplies power to a star connected load whose rating is $$12\sqrt 3 $$ kVA, $$0.8$$ pf(lag). The rating (in kVAR) of the delta c...
The resistance and reactance of a 100 kVA 11000|400 V, $$\triangle$$ - Y distribution transformer are 0.02 and 0.07 pu respectively. The phase impedance of the transformer referred...
A balanced delta connected load of $$\left( {8 + j6} \right)\Omega $$ per phase is connected to a $$400$$ $$V$$, $$50$$ $$Hz$$, $$3-$$phase supply lines. If the input power factor...
A balanced delta connected load of $$\left( {8 + j6} \right)$$ $$\Omega $$ per phase is connected to a $$400V,$$ $$50Hz,$$ $$3-$$ phase supply lines. If the input power factor is t...
A 3-phase, 11 kV, 50 Hz, 200 kW load has a power factor of 0.8 lag. A delta connected 3-phase capacitor is used to improve the power factor to unity. The capacitance power phase of...