Skip to content
Early access — you're among the first to try PYQLabs. Share feedback
Concept drill

symmetrical components

GATE Electrical Engineering · Power Systems - Symmetrical Components · 1996-2026

12
PYQs
83%
keyed
0
elite explanations
10
years appeared

Study anchor

Source-book anchor pending for this concept.

Practice action

Start latest PYQ

PYQs in this concept

All concepts →
2026 Q19

The initial three-phase voltage phasors ($\bar{V}_A$, $\bar{V}_B$, and $\bar{V}_C$) at a bus of a power network are as shown in Case-1. Due to a disturbance, the bus voltage phasor...

mediumanswer key
2022 PYQ

The valid positive, negative and zero sequence impedances (in p.u.), respectively, for a 220 kV, fully transported three-phase transmission line, from the given choices are

easyanswer keybasic explanation
2021 PYQ

Suppose $I_A, I_B$ and $I_C$ are a set of unbalanced current phasors in a three-phase system. The phase-B zero-sequence current $I_{B 0}=0.1 \angle 0^0$ p.u. If phase-A current $I_...

mediumanswer keybasic explanation
2018 Q20

The series impedance matrix of a short three-phase transmission line in phase coordinates is [Zs Zm Zm; Zm Zs Zm; Zm Zm Zs]. If the positive sequence impedance is (1 + j 10) Ω, and...

mediumanswer key
2018 PYQ

The series impedance matrix of a short three-phase transmission line in phase coordinates is $$\left[ {\matrix{ {{Z_s}} & {{Z_m}} & {{Z_m}} \cr {{Z_m}} & {{Z_s}} & {{Z_m}} \cr {{Z_...

easy
2014 PYQ

For a fully transposed transmission line

easyanswer key
2014 PYQ

In an unbalanced three phase system phase current $${{\rm I}_a} = 1\angle \left( { - {{90}^0}} \right)\,\,pu,\,\,$$ negative sequence current $$\,{{\rm I}_{b2}} = 4\angle \left( {...

mediumanswer key
2007 PYQ

Suppose we define a sequence transformation between ''a-b-c'' and ''p-n-0''' variables as follows: $$\left[ {\matrix{ {{f_a}} \cr {{f_b}} \cr {{f_c}} \cr } } \right] = k\left[ {\ma...

mediumanswer key
2006 PYQ

Three identical star connected resistors of $$1.0$$ $$p.u$$ are connected to an unbalanced $$3$$ phase supply. The load neutral is isolated. The symmetrical components of the line...

mediumanswer key
2000 PYQ

The plug setting of a negative sequence relay is $$0.2$$ $$A.$$ The current transformer ratio is $$5:1$$. The minimum value of line to line fault current for the operation of the r...

mediumanswer key
1999 PYQ

Determine the magnitudes of the symmetrical components ($${{{\rm I}_{R1}},\,{{\rm I}_{R2}}\,}$$ and $${{{\rm I}_{R0}}}$$) of the currents in a three phase (RYB) three wire system,...

medium
1996 PYQ

Unbalanced supply voltage given to a $$3-$$ phase, data-connected induction motor will cause

mediumanswer key