starting torque
GATE Electrical Engineering · Induction Motor · 1995-2025
Study anchor
Source-book anchor pending for this concept.
Practice action
Start latest PYQPYQs in this concept
All concepts →A 3-phase, 400 V, 4 pole, 50 Hz star connected induction motor has the following parameters referred to the stator: R = 1Ω, X_s = X'_r = 2Ω Stator resistance, magnetizing reactance...
A 3-phase star connected slip ring induction motor has the following parameters referred to the stator: $R_s = 3\, \Omega,\; X_s = 2\, \Omega,\; X_r' = 2\, \Omega,\; R_r' = 2.5\, \...
An 8 pole, $50 \mathrm{~Hz}, 3$ phase, slip-ring induction motor has an effective rotor resistance of $0.08 \Omega$ per phase. Its speed at maximum torque is 650 rpm . The addition...
A 220 V, 3-phase, 4-pole, 50 Hz inductor motor of wound rotor type is supplied at rated voltage and frequency. The stator resistance, magnetizing reactance, and core loss are negli...
A $$400$$ $$V,$$ $$50$$ $$Hz$$, $$4$$ pole, $$1400$$ $$rpm$$, star connected squirrel cage induction motor has the following parameters referred to the stator: $$R = 1.0\,\Omega ,{...
A three-phase squirrel cage induction motor has a starting torque of $$150\% $$ and a maximum torque of $$300\% $$ with respect to rated torque at rated voltage and rated frequency...
A three phase squirrel cage induction motor has a starting current of seven times the full load current and full load slip of $$5\% $$ If an auto-transformer is used for reduced vo...
A three phase squirrel cage induction motor has a starting current of seven times the full load current and full load slip of $$5\% $$ If a star-delta starter is used to start this...
A three phase squirrel cage induction motor has a starting current of seven times the full load current and full load slip of $$5\% $$ If a starting torque of $$0.5$$ per unit is r...
A $$3$$ phase, $$4$$ pole, $$400$$ $$V,$$ $$50$$ $$Hz,$$ star connected induction motor has following circuit parameters $${r_1} = 1.0\Omega ,\,{r_2} = 0.5\Omega ,$$ $${\mkern 1mu}...
A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full l...
Starting torque can be obtained in the case of a single phase induction motor with identical main and auxiliary windings by connecting
The following starting method for an induction motor is inferior view of the poor starting torque per ampere of the line current drawn:
An induction motor having full load torque of $$60$$ $$Nm$$ when delta-connected develops a starting torque of $$120$$ $$N$$-$$m.$$ For the same simply voltage, if the motor is cha...
An inverter capable of supplying a balanced three - phase variable voltage variable frequency output is feeding a three - phase induction motor rated for $$50$$ $$Hz$$ and $$440V.$...