All concepts →In the linear regulator circuit shown, the base to emitter voltage VBE of the BJT is 0.6 V. The Zener diode clamps the base voltage to 5.4 V. Ignore the biasing current of the Zene...
A three phase, 50 Hz, 6 pole induction motor runs at 960 rpm. The stator copper loss, core loss, and the rotational loss of the motor can be neglected. The percentage efficiency of...
A 5 kW, 220 V DC shunt motor has 0.5 Ω armature resistance including brushes. The motor draws a no-load current of 3 A. The field current is constant at 1 A. Assuming that the core...
A three phase, 50 Hz, 6 pole induction motor runs at 960 rpm. The stator copper loss, core loss, and the rotational loss of the motor can be neglected. The percentage efficiency of...
The power input to a $500 \mathrm{~V}, 50 \mathrm{~Hz}, 6$ pole, 3 phase induction motor running at 975 rpm is 40 kW . The stator losses are 1 kW . If the total friction and windag...
A 3-phase 900 kVA, 3 kV / √3 kV (Δ/Y), 50 Hz transformer has primary (high voltage side) resistance per phase of 0.3 Ω and secondary (low voltage side) resistance per phase of 0.02...
A 3-phase 900 kVA, 3 kV / $$\sqrt 3 $$ kV (Δ/Y), 50 Hz transformer has primary (high voltage side) resistance per phase of 0.3 Ω and secondary (low voltage side) resistance per pha...
A DC shunt generator delivers 45 A at a terminal voltage of 220 V. The armature and the shunt field resistance are 0.01 Ω and 44 Ω respectively. The stray losses are 375 W. The per...
A single-phase $$50$$ $$kVA,$$ $$250$$ $$V/500V$$ two winding transformer has an efficiency of $$95\% $$ at full load, unity power factor. If it is reconfigured as a $$500V/750V$$...
A $$3$$ phase, $$10$$ $$kW$$, $$400$$ $$V,$$ $$4$$ pole, $$50$$ $$Hz$$, star connected induction motor draws $$20$$ A on full load. Its no load and blocked rotor test data are give...
A $$300$$ $$kVA$$ transformer has $$95\% $$ efficiency at full load $$0.8$$ $$pf$$ lagging and $$96\% $$ efficiency at half load, unity $$pf.$$ The iron loss $$\left( {{P_i}} \righ...
A $$300$$ $$kVA$$ transformer has $$95\% $$ efficiency at full load $$0.8$$ $$pf$$ lagging and $$96\% $$ efficiency at half load, unity $$pf.$$ What is the maximum efficiency (in %...
The armature resistance of a permanent magnet dc motor is 0.8 $$\Omega$$. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of th...
A $$50$$ $$kW$$ synchronous motor is tested by driving it by another motor. When the excitation is not switched on, the driving motor takes $$800$$ $$W.$$ When the armature is shor...
The power input to a 415 V, 50 Hz, 6 pole, 3-phase induction motor running at 975 rpm is 40 kW. The stator losses are 1kW and friction and windage losses total 2 kW. The efficiency...
The efficiency of a 100 kVA transform is 0.98 at full as well as at half load. For this transformer at full load the copper loss.
A 3-phase squirrel cage induction motor has a full load efficiency of 0.8 and a maximum efficiency of 0.9. It is operated at a slip of 0.6 by applying a reduced voltage. The effici...
In a $$50$$ $$KVA,$$ $$11$$ $$KV/400$$ $$V$$ transformers, the iron and copper losses are $$500$$ $$W$$ and $$600$$ $$W$$ respectively under rated conditions. Calculate the efficie...