Skip to content
Early access — you're among the first to try PYQLabs. Share feedback
Concept drill

alternator

GATE Electrical Engineering · Synchronous Machines · 1993-2025

15
PYQs
87%
keyed
1
elite explanations
10
years appeared

Study anchor

Source-book anchor pending for this concept.

Practice action

Start latest PYQ

PYQs in this concept

All concepts →
2025 Q28

Instrument(s) required to synchronize an alternator to the grid is/are

easyanswer key
2025 PYQ

Instruments required to synchronize an alternator to the grid is/are

easyanswer keyelite explanation
2014 PYQ

A $$20$$-pole alternator is having $$180$$ identical stator slots with $$6$$ conductors in each slot. All the coils of a phase are in series. If the coils are connected to realize...

mediumanswer key
2011 PYQ

A negative sequence relay is commonly used to protect

easyanswer key
2009 PYQ

A field excitation of $$20A$$ in a certain alternator results in a armature current of $$400$$ $$A$$ in short circuit and a terminal voltage of $$2000$$ $$V$$ on open circuit. The...

easyanswer key
2001 PYQ

It is desirable to eliminate 5 th harmonic voltage from the phase voltage of an alternator. The coils should be short-pitched by an electrical angle of

easyanswer key
2001 PYQ

A $$50$$ Hz alternator is rated $$500$$ $$MVA,$$ $$20$$ $$kV,$$ with $${X_d} = 1.0$$ per unit and $$X'{'_d} = 0.2$$ per unit. It supplies a purely resistive load of $$400$$ $$MW$$...

mediumanswer key
2000 PYQ

The phase sequence of a three-phase alternator will reverse if

easyanswer key
2000 PYQ

A single-phase, 2000 V alternator has armature resistance and reactance of 0.8 ohms and 4.94 ohms respectively. The voltage regulation of the alternator at 100 A load at 0.8 leadin...

mediumanswer key
1999 PYQ

Higher synchronous reactance is preferred in the present day alternators, because one can have

mediumanswer key
1999 PYQ

A three phase alternator is wound with a 60 degree phase-spread armature windings and develops 300 kVA. If the armature is reconnected utilizing all the coils for single phase oper...

mediumanswer key
1998 PYQ

The armature of a single phase alternator is completely wound with T single turn coils distributed uniformly. The induced voltage in each turn is 2 Volts (rms). The emf of the whol...

mediumanswer key
1997 PYQ

A $$5MVA$$, $$11kV$$, $$3$$-phase star connected alternator is synchronized to the bus bars and is operating with an induced $$EMF$$ of $$125\% $$ of the rated voltage. If the load...

medium
1997 PYQ

A single-phase alternator has a synchronous reactance of $$2$$ $$ohms$$ and negligible resistance. If it supplies $$10$$ $$A$$ to a purely capacitive load at $$200V,$$ then generat...

medium
1993 PYQ

A three phase alternator has negligible stator resistance. A short circuit test is conducted on this alternator. At a particular speed a field current of $${{\rm I}_f}$$ is require...

mediumanswer key